First reported in 2010 using the conventional whole cell patch clamp technique milnes et al. To identify potential herg liabilities early in drug. Typically, herg potencies measured by automated and manual electrophysiology are in good agreement. Metrion is located within the cambridge bio cluster, one of europes largest bioscience research hubs. Patch clamp technique is the gold standard for carrying. Patchclamp electrophysiology remains the functional gold standard for testing the interaction of compounds with the herg channel, but the cost of these assays remains high. Implementation of a kinetic herg assay protocol using qpatch. Why are there current fluctuations in herg patch clamp assay. Sep 02, 2014 automated patch clamp electrophysiology is an emerging technique for identifying cardiac ion channel liabilities. N4 kit comparison results hts assay robustnessic 50. Automated patchclamp methods for the herg cardiac potassium channel. Automated patchclamp methods for the herg cardiac potassium. In this study, highthroughput electrophysiological recordings of human embryonic kidney hek 293 cells and chinese hamster ovary cho cells stably expressing human etheragogo related gene herg were performed utilizing an automated 384well patch clamp system, which records up to 384 cells simultaneously.
Cell and tissue culture, electrophysiology, live cell imaging, drug delivery, patch clamp technique, transfection, electrocardiogram, cell proliferation assay. Patch clamp technique method electrophysiology technique. Protocols are available for single dose testing and doseresponse curves. The correlation between in vitro herg ic 50, drug exposure. Nov 17, 2004 electrophysiology is the most reliable in vitro screening method for identifying potential cardiac herg liabilities, but only the recent advent of planar electrodebased voltage clamp electrophysiology promises sufficient throughput to support the drug testing needs of most drug discovery programs. This allows voltage clamp control of the cell and is commonly referred to as a perforated wholecell patch clamp recording. Automated electrophysiological patch clamp allows assessment of.
Covid19 is an emerging, rapidly evolving situation. Early identification of herg liability in drug discovery. Implementation of a kinetic herg assay protocol using. Traditionally, electrophysiologists have relied on the goldstandard assay of patchclamp electrophysiology in mammalian cells or twoelectrode voltage clamp in xenopus oocytes. The flipr potassium assay kit shows similar ic 50 values to the nonhomogeneous assay but has significantly higher assay window as indicated by max values. Evaluation of the rubidium efflux assay for preclinical. The correlation between in vitro herg ic 50, drug exposure, qt prolongation in the thorough qt clinical trial and risk of tdp has greatly reduced drug withdrawals due to tdp. Traditionally, electrophysiologists have relied on the goldstandard assay of patch clamp electrophysiology in mammalian cells or twoelectrode voltage clamp in xenopus oocytes. Electrophysiological analysis of mammalian cells expressing herg using automated 384well patch clamp yuji haraguchi1, atsushi ohtsuki1,2, takayuki oka1,2 and tatsuya shimizu1 abstract background. Automated patch clamp electrophysiology experiments were carried out using the ionworks system as described. The flipr potassium assay kit shows similar ic 50 values to the. Performance of the predictor fluorescence polarization. This method is considered comparison of the predictor herg fp assay to the patch clamp method has previously been shown to correlate very closely.
A single cell is then positioned on the hole by suction and a tight connection gigaseal is formed. This has led to further publications with more focus on specific cell and. The qpatch htx is a highthroughput and automated electrophysiology platform. Electrophysiology remains the gold standard for the functional assessment of ion. Measurement of k v currents in an automated 384well patch clamp system. In addition, we evaluated 19 blinded compounds at 10 m in the. A highthroughput electrophysiology assay identifies. In addition to confirming the activity of potential hits from high or medium throughput screens, manual patch clamping can be used to assess mechanism of action of compounds and to determine the effects of compounds on the. The qpatch htx and the syncropatch 384pe systems deliver high quality. Sucrose gap method with 2 electrodes was the standard voltage clamp technique when used the cardiac tissue. From ecg to ionic currents hergworkshops jimdopage. Invitrogen predictor herg fluorescence polarization assay page 2 of 17 for technical support for this or other drug discovery products, dial 7606037200, option 3, extension 40266 corporate.
Metrion biosciences ion channel screening integrated drug. The metrion biosciences team recently produced an application note reporting the successful validation of the milnes voltage protocol for herg screening using a qpatch 48 automated patch clamp apc assay platform. It allows highresolution current recordings not only of whole cells, but also of excised cellular patches. Channels 89 a major limitation of all automated electrophysiology platforms is the high cost of the instruments and consumables. Predictor herg fluorescence polarization assay kit. Recording temperature affects pharmacology outcomes.
Comparison of ic 50 values of the flipr potassium assay kit on the flipr tetra system and electrophysiology data on the ionworks barracuda system in addition, three compounds were used to evaluate performance against another thalliumbased assay kit, the fluxor potassium ion channel assay figure 6. Our manual and automated patch clamp assays reveal interactions of compounds with cardiac herg channels. Biochemical herg assays thermo fisher scientific us. Throughput according to our customers needs from one compound to hts screening. To identify potential herg liabilities early in drug discovery programs and thus avoid problems with herg channel interactions for latestage compounds, it has become common practice in drug discovery programs to start testing compounds relatively early during the drug discovery. An in vitro electrophysiological assay system, which can assess compound effects and thus show cardiotoxicity including arrhythmia risks of test drugs, is an essential method in the field of. Electrophysiology from greek, elektron, amber see the etymology of electron. The procedure involves pressing a glass micropipette. Traditionally herg screening is performed with a whole cell voltage patch clamp apparatus. While the patch clamp method works very well for identifying compounds that block potassium ion flow through herg channels, it requires a high resistance seal be made. Another concern with regard to the automated platforms is the potential for results that are inconsistent with those from conventional voltage clamp assays.
Although patchclamp electrophysiology remains the gold standard for determining the interaction of compounds with the function of the herg channel, radioligand displacement assays have proven to be. Automated electrophysiological patch clamp allows assessment of herg channel. The patch clamp technique is a refinement of the voltage clamp. Our state of the art laboratories at granta park house high quality facilities for native and engineered. Planar patch clamp is a novel method developed for high throughput electrophysiology. The predictor herg fluorescence polarization assay kit provides a set of validated components to perform herg channel biochemical binding studies in the absence of radioligand. Even singlechannel opening events can be investigated. Manual patch clamp assay manual patch clamping is the goldstandard for the investigation of ion channel activity.
The human etheragogo related gene herg encodes the inward rectifying. Our manual and automated patch clamp assays reveal interactions of compounds with cardiac herg channels herg currents are recorded from stably transfected cho cells. The assay is based on the principle of fluorescence polarization, where a redshifted fluorescent tracer displays a high polarization when bound to the herg channel and a low polarization. The rank order of herg inhibitors determined in flipr potassium kit assay is identical to that in the electrophysiology assay figure 5. That technique required a huge effort, training, luckiness and patience, but good results. The scorpion toxin bekm1 5, 6 blocks herg preferentially through closed channels 2, 7. Using automated patch clamp electrophysiology platforms in. Manual patch clamp evaluation of herg channel pharmacology. A number of herg assays to assess cardiac safety have been developed e. The patch clamp technique is a laboratory technique in electrophysiology used to study ionic currents in individual isolated living cells, tissue sections, or patches of cell membrane. The qpatch performs up to 48 independent patch clamp experiments in parallel in a 48channel chip array with microfluidic chambers qplate. Expertise with wholecell, insideout, outsideout and cell attached patch clamp electrophysiological configurations.
Another concern with regard to the automated platforms is the potential for results that are inconsistent with those from. Population patch clamp ppc is a novel high throughput planar array electrophysiology technique that allows ionic currents to be recorded from populations of cells under voltage clamp. The protocol described in this unit is designed to. The voltage clamp was difficult both teoretically and practically, not a lot of people could have experience doing that. Patchclamp electrophysiology is regarded as the gold standard for measuring ion channel activity and pharmacology and is based on analysing membrane properties of a single cell. An in vitro electrophysiological assay system, which can assess compound.
The metrion biosciences team recently produced an application note reporting the successful validation of the milnes voltage protocol for herg screening using a qpatch 48 automated patch clamp apc. Creative bioarray uses the stateoftheart automated qpatchht system to provide a higherthroughput herg safety assay with better consistency at a lower cost. Technologies as automated patch clamp electrophysiology measurements. View larger version preliminary crosschannel selectivity. Electrophysiological analysis of mammalian cells expressing herg. In addition to confirming the activity of potential hits from high or medium throughput. The assay was designed to identify potential herg channel blockers by producing data that accurately correlates with patch clamp electrophysiology studies. A patch clamp recording of current reveals transitions between two conductance states of a single ion channel. Inhibition of herg current at 1 um by patch clamp electrophysiology assay. Using automated patch clamp electrophysiology platforms in pain.
Metrion biosciences ion channel screening integrated. Automated patch clamp apc technology was first developed at the turn of the millennium. The herg safety service is performed by our parent company, evotec, and is a cellbased assay which employs the qpatch htx system sophion bioscience as or the syncropatch 384pe nanion. Patch clamp technique is the gold standard for carrying out. This method is considered comparison of the predictor herg fp assay to the patch clamp method has previously.
In this study, highthroughput electrophysiological recordings of human embryonic kidney hek 293 cells and chinese hamster ovary cho cells stably expressing human. In addition, we evaluated 19 blinded compounds at 10 m in the rb efflux assay, and compared results to those using patch clamp electrophysiology and the dofetilide displacement binding assay. Both filtration and homogeneous flashblue herg binding assay have been optimized with 125 ibekm1 panels 7. A history of the role of the herg channel in cardiac risk.
Cardiac electrophysiology has been developed from ecg to membrane ionic currents via the action potential, or technically surface electrical integrated measurement to patch clamp techniques, vial micro electrode technique. The assay was designed to identify potential herg channel blockers by producing data that accurately correlates with patchclamp electrophysiology studies. Automated tight seal electrophysiology for assessing the. The herg safety service is performed by our parent company, evotec, and is a cellbased assay which employs the qpatch htx system sophion bioscience as or the syncropatch 384pe nanion technologies as automated patch clamp electrophysiology measurements. Fluorescencebased assays predominate in primary screening of full diversity libraries, with greatest use made of fluorescentbased membrane potential assays. The procedure involves pressing a glass micropipette against a cell in order to isolate a small patch of membrane that contains one or more ion channels. The report also examines assay technologies preferences used today in the study of ion channels targets today figure 2. Automated patch clamp an overview sciencedirect topics. Role of herg potassium channel assays in drug development.
With expertise with wholecell, insideout, outsideout and cellattached patch clamp electrophysiological configurations, charles river offers a variety of cardiovascular and central nervous system in vitro. In the automated patchclamp measurements performed here, kv. Cardiac electrophysiology has been developed from ecg to membrane ionic currents via the action potential, or technically surface electrical integrated measurement to patch clamp techniques, vial. Why are there current fluctuations in herg patch clamp. Electrophysiological analysis of mammalian cells expressing herg using automated 384wellpatchclamp yuji haraguchi1, atsushi ohtsuki1,2, takayuki oka1,2 and tatsuya shimizu1 abstract. The protocol described in this unit is designed to assess the effects of new chemical entities after acute or long. Instead of positioning a pipette on an adherent cell, cell suspension is pipetted on a chip containing a microstructured aperture. Characterization of herg channel blockers using the flipr. The development of the patch clamp technique in the late 1970s has given electrophysiologists new prospects. Electrophysiological analysis of mammalian cells expressing. Typically, herg potencies measured by automated and manual. An in vitro electrophysiological assay system, which can assess compound effects and thus show.
Our manual and automated patch clamp assays reveal interactions of compounds with cardiac herg channels herg currents are recorded from stably transfected cho cells protocols are available for single dose testing and doseresponse curves throughput according to our customers needs herg patch clamp. The herg safety service is performed at our parent company, evotec, and is a cellbased assay which employs the qpatch htx system sophion bioscience as or the syncropatch 384pe nanion. Patch clamp recording is an extremely useful technique for investigating the biophysical properties of the ion channels that control neuronal activation. The assay is based on the principle of fluorescence polarization where a redshifted fluorescent tracer is displaced from the herg channel by compounds that bind to the channel. Especially in neuroscience, the physiology of ion channels has always been a major topic of interest. Oct 16, 2016 the patch clamp technique is a refinement of the voltage clamp. That technique required a huge effort, training, luckiness and patience, but good results acceptable for publication were not easily obtained. The increased throughput it afforded promised a new paradigm in ion channel recordings, offering the potential to overcome the time. Malaria box compounds were tested for inhibition of the human ether a gogo related gene herg, kv11.